Sewer design calculations

Sewer design calculations

เครื่องมือ | Transparent Blue

เล่นบน PC ผ่าน BlueStacks - Android Gaming Platform ที่ได้รับความไว้วางใจจากเกมเมอร์ 500 ล้านคนทั่วโลก

Page Modified on: 2 กุมภาพันธ์ 2557

Play Sewer design calculations on PC

Calculate the design diameter and slope for a section of sewer pipe.

The Manning Equation is used for Calculation of Pipe Diameter and Slope.

Input data are design flow, elevations of ground initial and final.

The app can be used in the SI or US units.

Example: The design flow rate for a section of storm sewer between two manholes is: Qdes = 10 l/s. Find a combination of a standard pipe diameter and pipe slope to use for this section of sewer to meet the criteria of minimun tractive force.

The required minimum tractive force for sanitary sewer in the app is considered as 2 N/m2.

See solution of example in the screenshot.
- Initial ground elevation = 10 m (ground elevation of initial and final manholes is used to calculate the ground slope and check that slope of the pipe is not less than ground).
- Final ground elevation = 9 m
- Length of pipe = 60 m
- Desired flow = 40 liters per seconds

And as a result of the design, after pressing the calculate button, we get the following results:

Slope: 0.02 m / m, equivalent to 2%
Pipe diameter: 0.3 m
height of water in the pipe (depth / diameter): 40%

เล่น Sewer design calculations บน PC ได้ง่ายกว่า

  • ดาวน์โหลดและติดตั้ง BlueStacks บน PC ของคุณ

  • ลงชื่อเข้าใช้แอคเคาท์ Google เพื่อเข้าสู่ Play Store หรือทำในภายหลัง

  • ค้นหา Sewer design calculations ในช่องค้นหาด้านขวาบนของโปรแกรม

  • คลิกเพื่อติดตั้ง Sewer design calculations จากผลการค้นหา

  • ลงชื่อเข้าใช้บัญชี Google Account (หากยังไม่ได้ทำในขั้นที่ 2) เพื่อติดตั้ง Sewer design calculations

  • คลิกที่ไอคอน Sewer design calculations ในหน้าจอเพื่อเริ่มเล่น

ดูวิดีโอ